6L Fluorine Free Foam Fire Extinguisher

    6L Fluorine Free Foam Fire Extinguisher

      Product form

      The 6L Fluorine Free Foam is the replacement for all older foam types used before 2026. It is fluorine free and complies to the requirements of NEA. Foam fire extinguishers are exceptionally easier to handle when fighting against class B fires. The foam barrier naturally prevents oxygen from feeding the fire and preventing reigntion.

      • Wall bracket included
      • SCDF Fire Code Compliant
      • Best choice against Class B fires
      • 5 Year warranty against leaks

      $130.00

        • Guaranteed secure & safe checkout.

        WarrantyWarranty

        We offer a 5-year limited warranty to repair or replace any defective material or component. It does not cover any issues due to delibrate discharge, testing, normal wear and tear, misuse or loss / theft of the product.

        The 6L Fluorine Free Foam is the replacement for all older foam types used before 2026. It is fluorine free and complies to the requirements of NEA. Foam fire extinguishers are exceptionally easier to handle when fighting against class B fires. The foam barrier naturally prevents oxygen from feeding the fire and preventing reigntion.

        Technical Specifications

        • Capacity
          6L Fluorine Free Foam

          Model
          FEL-FFA-FF06

          Propellant
          Nitrogen

          Body Diameter
          162mm

          App Total Weight
          10.0KG

          Packing Dimension
          170x170x535mm(1 per box)

        • Fire Rating
          21A 144B

          Discharge Distance
          > Est 3m

          App Discharge Time
          Est 15+ Sec

          Working Pressure
          14Bar

          Test Pressure
          25Bar

          Operating Temp
          5°C to 60°C

        Easy to use.

        Performance

        Class A

        Class A

        Tested for 21A rating under laboratory conditions.
        A 21A fire is 2.1m x 0.5m x 0.5m

        Can easily put out a class A fire the size of a bus stop green bin.

        *The difficulty of fighting a fire depends on flammability of the surrounding materials, windspeed and the skill of the fire fighter. These are rough estimates of what can be put out.

        Class B

        Class B

        Tested for 144B under laboratory conditions.
        A 144B fire is 96L of flammable liquid

        *The difficulty of fighting a fire depends on flammability of the surrounding materials, windspeed and the skill of the fire fighter. These are rough estimates of what can be put out.

        Electric

        Electric

        Does not conduct electricity. SCDF recommends electricity to be turned off before attempting any fire fighting as the fire may reignite.

        How many do I need

        Each 6L Fluorine Free Foam Fire Extinguisher is rated at 21A which means it can cover around 4300 sqft / 315 sqm. To comply with SCDF fire code, the entire area must be covered and no person should have to walk more than 15m to reach a fire extinguisher.

        When to use this?

        The 6L fluorine free fire extinguisher is most commonly seen at areas that store a lot of flammable liquids.

        Frequently asked questions

        Will this fire extinguisher comply to NEA's requirements?

        Fluorine exists naturally so a very trace amount will always be present. Rest assured, this fire extinguisher will comply to NEA's requirements.

        Can I still use my old fluorinated foam fire extinguishers that I bought before 2026?

        Yes, you can until you need to do refilling or when your building undergoes A&A or renovation.

        Is this safe to use on electrical equipment?

        Yes. This fire extinguisher has been dielectrically tested which means it is safe to use on electrical equipment. SCDF would like to remind everyone that when safe to do so, the source of fire should first be shut off. This includes electrical and gas sources.

        Can I test to see if it is working?

        All fire extinguishers should not be tested. This will void its warranty. Even the smallest discharge can cause a complete leakage over time. This is intended for safety reasons and it is also why fire extinguishers must be recharged upon any partial or complete usage.

        How do I maintain this?

        The annual maintenance is a SCDF requirement for commercial users. Fire extinguishers have to be maintained at a SCDF approved workshop. You can bring this fire extinguisher to our partner at 9 Fan Yoong Road. Prior appointment is required. Make an appointment at 87744355

        What's in the box?